S-8252AAD-M6T1U Battery Management LITHIUM-ION BATTERY PROTECTION 2 CELL
1.Features
High-accuracy voltage detection function for each cell
Overcharge detection voltage n (n = 1, 2) 3.550 V to 4.600 V (5 mV steps) Accuracy 20 mV (Ta = 25°C)
Accuracy 25 mV (Ta = 10°C to 60°C)
Overcharge release voltage n (n = 1, 2) 3.150 V to 4.600 V*1 Accuracy 30 mV
Overdischarge detection voltage n (n = 1, 2) 2.000 V to 3.000 V (10 mV steps) Accuracy 50 mV
Overdischarge release voltage n (n = 1, 2) 2.000 V to 3.400 V*2 Accuracy 100 mV
Discharge overcurrent detection voltage 0.050 V to 0.400 V (10 mV steps) Accuracy 10 mV
Load short-circuiting detection voltage 0.500 V to 0.900 V (50 mV steps) Accuracy 100 mV
Charge overcurrent detection voltage 0.400 V to 0.050 V (25 mV steps) Accuracy 20 mV
Charge overcurrent detection function "available" / "unavailable" is selectable.
Detection delay times are generated only by an internal circuit (external capacitors are unnecessary).
Accuracy 20%
High-withstand voltage (VM pin and CO pin: Absolute maximum rating = 28 V)
0 V battery charge function "available" / "unavailable" is selectable.
Power-down function "available" / "unavailable" is selectable.
Wide operation temperature range Ta = 40°C to 85°C
Low current consumption
During operation 8.0 A max. (Ta = 25°C)
During power-down 0.1 A max. (Ta = 25°C)
Lead-free (Sn 100%), halogen-free
*1. Overcharge release voltage = Overcharge detection voltage Overcharge hysteresis voltage
(Overcharge hysteresis voltage n (n = 1, 2) can be selected as 0 V or from a range of 0.1 V to 0.4 V in 50 mV steps.)
*2. Overdischarge release voltage = Overdischarge detection voltage Overdischarge hysteresis voltage
(Overdischarge hysteresis voltage n (n = 1, 2) can be selected as 0 V or from a range of 0.1 V to 0.7 V in 100 mV
steps.)
2.Applications
• Lithium-ion rechargeable battery pack
• Lithium polymer rechargeable battery pack
3.Block Diagram
4.Why choose us?
100% new and originao with Advantage price
High efficiency
Fast Delivery
Professional team service
10 Years Experience Electronic components
Electronic components Agent
Advantage logistic discount
Excellent After-sales Service
MOQ: | 10PCS |
Price: | NEGOTIABLE |
Standard Packaging: | 3000PCS/REEL |
Delivery Period: | 2-3DAYS |
Payment Method: | T/T |
Supply Capacity: | 12000PCS/WEEK |
S-8252AAD-M6T1U Battery Management LITHIUM-ION BATTERY PROTECTION 2 CELL
1.Features
High-accuracy voltage detection function for each cell
Overcharge detection voltage n (n = 1, 2) 3.550 V to 4.600 V (5 mV steps) Accuracy 20 mV (Ta = 25°C)
Accuracy 25 mV (Ta = 10°C to 60°C)
Overcharge release voltage n (n = 1, 2) 3.150 V to 4.600 V*1 Accuracy 30 mV
Overdischarge detection voltage n (n = 1, 2) 2.000 V to 3.000 V (10 mV steps) Accuracy 50 mV
Overdischarge release voltage n (n = 1, 2) 2.000 V to 3.400 V*2 Accuracy 100 mV
Discharge overcurrent detection voltage 0.050 V to 0.400 V (10 mV steps) Accuracy 10 mV
Load short-circuiting detection voltage 0.500 V to 0.900 V (50 mV steps) Accuracy 100 mV
Charge overcurrent detection voltage 0.400 V to 0.050 V (25 mV steps) Accuracy 20 mV
Charge overcurrent detection function "available" / "unavailable" is selectable.
Detection delay times are generated only by an internal circuit (external capacitors are unnecessary).
Accuracy 20%
High-withstand voltage (VM pin and CO pin: Absolute maximum rating = 28 V)
0 V battery charge function "available" / "unavailable" is selectable.
Power-down function "available" / "unavailable" is selectable.
Wide operation temperature range Ta = 40°C to 85°C
Low current consumption
During operation 8.0 A max. (Ta = 25°C)
During power-down 0.1 A max. (Ta = 25°C)
Lead-free (Sn 100%), halogen-free
*1. Overcharge release voltage = Overcharge detection voltage Overcharge hysteresis voltage
(Overcharge hysteresis voltage n (n = 1, 2) can be selected as 0 V or from a range of 0.1 V to 0.4 V in 50 mV steps.)
*2. Overdischarge release voltage = Overdischarge detection voltage Overdischarge hysteresis voltage
(Overdischarge hysteresis voltage n (n = 1, 2) can be selected as 0 V or from a range of 0.1 V to 0.7 V in 100 mV
steps.)
2.Applications
• Lithium-ion rechargeable battery pack
• Lithium polymer rechargeable battery pack
3.Block Diagram
4.Why choose us?
100% new and originao with Advantage price
High efficiency
Fast Delivery
Professional team service
10 Years Experience Electronic components
Electronic components Agent
Advantage logistic discount
Excellent After-sales Service